Details
Rat Interleukin 1 beta (IL-1β) ELISA Kit — Catalogue Number SL0402Ra
Intended use
This kit is intended for the quantitative determination of rat interleukin 1 beta (IL-1β) levels in rat serum, plasma, cell culture supernatants, body fluid and tissue homogenate. It is a Sandwich-ELISA for research use only and is not intended for therapeutic or diagnostic applications.
Principle
This ELISA kit uses Sandwich-ELISA as the method. The microelisa stripplate provided in the kit has been pre-coated with an antibody specific to IL-1β. Standards or samples are added to the appropriate microelisa stripplate wells and combined with the specific antibody. Then a horseradish peroxidase (HRP)-conjugated antibody specific for IL-1β is added to each well and incubated, and free components are washed away. The TMB substrate solution is added to each well: only those wells that contain IL-1β and HRP-conjugated IL-1β antibody appear blue in colour and then turn yellow after the addition of the stop solution. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The OD value is proportional to the concentration of IL-1β, and the concentration in the samples is calculated by comparing the OD of the samples with the standard curve.
Kit components
| Component | 96 tests | Storage |
| User manual | 1 | Room temperature |
| Closure plate membrane | 2 | Room temperature |
| Sealed bags | 1 | Room temperature |
| Microelisa stripplate | 1 | 2-8 ℃ |
| Standard: 108 pg/mL | 0.5 mL × 1 bottle | 2-8 ℃ |
| Standard diluent | 1.5 mL × 1 bottle | 2-8 ℃ |
| HRP-conjugate reagent | 6 mL × 1 bottle | 2-8 ℃ |
| Sample diluent | 6 mL × 1 bottle | 2-8 ℃ |
| Chromogen solution A | 6 mL × 1 bottle | 2-8 ℃ |
| Chromogen solution B | 6 mL × 1 bottle | 2-8 ℃ |
| Stop solution | 6 mL × 1 bottle | 2-8 ℃ |
| Wash solution | 20 mL (30×) × 1 bottle | 2-8 ℃ |
Specifications
| Parameter | Value |
| Catalogue number | SL0402Ra |
| Assay type | Sandwich ELISA, quantitative |
| Detection method | Colorimetric, HRP/TMB |
| Wavelength | 450 nm |
| Assay range | 1 pg/mL - 80 pg/mL |
| Sensitivity | 0.1 pg/mL |
| Standard concentration | 108 pg/mL |
| Standard curve points | 108, 72, 48, 24, 12 and 6 pg/mL |
| Sample volume | 10 μL of sample plus 40 μL of sample diluent (dilution factor 5) |
| Sample types | Serum, plasma, urine, cerebrospinal fluid and pleuroperitoneal fluid, cell culture supernatant and tissue homogenate |
| Precision | Intra-assay CV < 10 %; inter-assay CV < 12 % |
| Storage | 2-8 ℃ |
| Validity | 6 months |
| Kit size | 48 T / 96 T |
Assay procedure summary
1. Dilute the standard with the standard diluent to obtain the concentrations 108, 72, 48, 24, 12 and 6 pg/mL; pipette 50 μL of each concentration into the microplate wells, using two wells per concentration.
2. Leave one well empty as the blank control. In the sample wells add 40 μL of sample dilution buffer and 10 μL of sample (dilution factor 5), load the liquid onto the bottom of the well without touching the wall and mix gently.
3. Seal the plate with the closure plate membrane and incubate for 30 min at 37 ℃.
4. Dilute the concentrated wash solution with distilled water (30 times for the 96 T kit and 20 times for the 48 T kit).
5. Peel off the closure plate membrane, aspirate the liquid and refill the wells with the wash solution; discard the wash solution after 30 s and repeat the washing 5 times.
6. Add 50 μL of HRP-conjugate reagent to each well except the blank control well.
7. Incubate as described in step 3 and wash as described in step 5.
8. Add 50 μL of chromogen solution A and 50 μL of chromogen solution B to each well, mix gently and incubate for 15 min at 37 ℃, protected from light.
9. Add 50 μL of stop solution to each well; the colour changes from blue to yellow.
10. Read the absorbance at 450 nm with a microtiter plate reader, setting the blank control well to zero. The reading has to be completed within 15 min after adding the stop solution.
Typical performance
Intra-assay precision (within one assay): three samples with low, middle and high level of rat IL-1β were tested 20 times on one plate; CV < 10 %.
Inter-assay precision (between assays): three samples with low, middle and high level of rat IL-1β were tested on 3 different plates with 8 replicates in each plate; CV < 12 %.
The standard curve is plotted with the known concentrations of the rat IL-1β standard on the x-axis and the corresponding OD readings on the y-axis. The concentration of the samples is read from the curve and multiplied by the total dilution factor. The diagram in the instruction manual is for reference only.
Ordering & shipping
References (29)
Journal: Farouk K. El-Baz, Abeer Salama, Sami I. Ali & Rania Elgohary. 2022/12/30.
Journal: hmed A. Sedik, Azza Hassan, and Abeer Salama1. 2023.
Moexipril Improves Renal Ischemia/Reperfusion Injury in Adult Male Rats
Journal: Tandoğan Yİ, Aydin O, Pehlivanli F, Aydinuraz K, Daphan ÇE, Kaplan İ.. 2025.
Journal: Subhojit Paul, Anamika Gangwar, Kalpana Bhargava, Yasmin Ahmad. 2020.
Journal: Tavaci T, Halici Z, Cadirci E, Ozkaraca M, Kasali K.. 2025.
Journal: Rahma Zedan, Magdy M. Awny, Karema Abu‐Elfotuh, Azza A. Ali. 2023.
Journal: Alyae M.S. Gabal, Nagwan Samy El-Zaeem, Heba Barakat, Hadeer H. Maria. 2025.
Journal: Mostafa Shalaby, Amer Ramadan, Sahar S. Abd El‐Rahman, Hany M. Fayed. 2024.
Journal: Zahraa I. J. Shubber, Qayssar Joudah Fadheel. 2025.
Partial purchase records (13)
| Username | Quantity | bought time |
| Na*** | 4 | 2024-09-05 |
| Za*** | 3 | 2024-04-26 |
| Vi*** | 2 | 2023-09-14 |
| Ha*** | 1 | 2022-01-11 |
| Ja*** | 3 | 2021-11-16 |
Leave a message
+86 0571 56623320
[email protected]
+86 18668110335

Scan Wechat Qrcode
