Details
Product Description:
Caspase-1 (cysteine-requiring aspartate protease 1) is the only caspase that cleaves the precursors of IL-1β and IL-18 to release the active cytokines. The 45 kDa pro-caspase-1 is cleaved into 20 kDa and 10 kDa fragments, which first form a heterodimer and then a tetramer that carries the protease activity. Caspase-1 regulates apoptosis by cleaving Bcl-XL and modulates cytokine-mediated immune and inflammatory responses by processing cytokine precursors.
The assay is based on the specific hydrolysis of the caspase-1 peptide substrate N-acetyl-Tyr-Val-Ala-Asp-pNA (Ac-YVAD-pNA), which releases free p-nitroaniline (pNA). The released pNA is yellow and shows a maximum absorption peak at 405 nm, so caspase-1 activity is measured by visible-light colorimetry, and the absorbance value corresponds to the hydrolytic activity of caspase-1. The reaction volume is 100 μL. With the reagents supplied, 50 or 100 samples can be assayed in addition to the standard curve. The kit is intended for the determination of caspase-1 activity in mammalian tissues and cells.
Specifications:
| Parameter | Value |
| Detection method | Colorimetric |
| Wavelength | 405 nm (maximum absorption peak); measurement within 400-450 nm is also acceptable |
| Detection instrument | UV-Vis spectrophotometer with 1 mL glass cuvette (1 cm light path); a microplate reader with a 96-well plate can also be used |
| Assay time | 3 h |
| Principle | pNA colorimetric method |
| Research area | Apoptosis |
| Response type | Increasing (absorbance rises with enzyme activity) |
| Detection limit (LOD) | 10 U/mL |
| Linear range | 12.5-500 U/mL |
| Sample type | Cells; also applicable to mammalian tissue and cell samples |
| Reaction volume | 100 μL |
| Kit sizes | 20 T / 50 T / 100 T |
| Storage | -20 ℃ |
| Shipping | Frozen |
Kit Components:
| Component | 50 T | 100 T | Storage |
| Lysis buffer | 10 mL | 20 mL | 4 ℃ |
| Reaction buffer | 5 mL | 10 mL | 4 ℃ |
| 2 mM Ac-YVAD-pNA substrate | 0.25 mL | 0.5 mL | -20 ℃, protected from light |
| 10 mM pNA standard | 0.25 mL | 0.5 mL | -20 ℃, protected from light |
The volumes listed in the table correspond to the 100 T size; the 50 T size contains half of each volume.
Storage & Shelf Life:
The kit is shipped frozen. Upon arrival, store each component as listed in the Kit Components table: keep the buffers at 4 ℃ and the substrate and pNA standard at -20 ℃ protected from light. Under the recommended storage conditions the kit is stable for 6 months.
Notes:
1. This product is for research use only. It is not intended for pharmaceutical, clinical diagnostic or therapeutic use, nor for food or cosmetic applications. Do not store it in ordinary residential areas.
2. For your safety and health, please wear a lab coat, disposable gloves and a mask while handling the reagents.
3. Experimental results can be affected by many factors. Handling related to this product is limited to the product itself and does not cover any other compensation.
4. The maximum absorption wavelength is 405 nm; if a 405 nm filter is not available, the absorbance can be read within 400-450 nm.