Home > Assay-Detection Kit > Bradford Protein Assay Kit

Bradford Protein Assay Kit

Bradford Protein Assay Kit
Total $50

Product Summary

Alias:Bradford法蛋白浓度测定试剂盒

NO.:AK0697

Method:Bradford

Wavelength:595nm

Shelf life:12 months

Storage:BSA-20℃,others 2-8℃

    Number:

Details

Product Description:

The kit determines the protein concentration of a sample with the Bradford method. Coomassie Brilliant Blue G-250 dye binds to protein in acidic solution and the position of the dye's maximum absorption peak shifts from 465 nm to 595 nm. Within a certain concentration range the absorbance measured at 595 nm (A595) is proportional to the protein concentration of the sample, so the protein content is obtained from a standard curve prepared with the protein standard supplied with the kit.

The Bradford assay is not affected by most of the chemicals present in a sample. The concentration of 2-mercaptoethanol in the sample may be as high as 1 M and the concentration of dithiothreitol (DTT) as high as 5 mM without influencing the result. Higher concentrations of detergents do interfere: the concentration of SDS has to stay below 0.1 %, that of Triton X-100 below 0.1 % and that of Tween 20, Tween 60 and Tween 80 below 0.06 %. For samples containing detergents, a BCA protein assay kit is recommended.

Two formats are described for the kit. In the microplate format the samples and the standards are placed in the wells of a 96-well plate, the diluted dye reagent is added and the absorbance is read with a microplate reader. When no microplate reader is available the colour reaction can be carried out in centrifuge tubes and the absorbance read in a cuvette with a spectrophotometer. The kit is intended for the quantitative determination of protein concentration in biological samples.

Specifications:

Parameter Value
Detection method Colorimetric (Coomassie Brilliant Blue G-250)
Wavelength 595 nm; the absorbance can also be read at any wavelength between 560 nm and 610 nm
Detection instrument Microplate reader with a 96-well plate, or a visible spectrophotometer with a cuvette
Principle Bradford method
Research area Protein extraction and quantification
Response type Increasing (absorbance rises with protein concentration)
Standard concentrations 0, 0.02, 0.04, 0.06, 0.08, 0.12, 0.16 and 0.2 mg/mL BSA
Protein standard 5 mg/mL BSA, 1 mL
Kit size 100 T (2,500 microplate wells)
Storage 2-8 ℃ for the dye solution and the PBS diluent; -20 ℃ for the protein standard
Shipping Refrigerated
Shelf life 12 months

Kit Components:

Component Size Storage
5× G250 dye solution 100 mL 2-8 ℃
PBS diluent 30 mL 2-8 ℃
Protein standard (5 mg/mL BSA) 1 mL -20 ℃

The protein standard is supplied as a separate accessory; store it at -20 ℃ immediately after receipt.

Equipment and consumables required but not supplied: microplate reader (or visible spectrophotometer with cuvette), 96-well plate, adjustable pipettes, distilled water and clean tubes.

Storage & Shelf Life:

The kit is shipped refrigerated. On arrival store the 5× G250 dye solution and the PBS diluent at 2-8 ℃ and the protein standard at -20 ℃. Under the recommended storage conditions the kit is stable for 12 months. The 1× G250 working dye prepared by diluting the 5× dye solution with double-distilled water can be kept at 4 ℃ for one week.

Notes:

1. This product is for research use only. It is not intended for pharmaceutical, clinical diagnostic or therapeutic use, nor for food or cosmetic applications. Do not store it in ordinary residential areas.

2. For your safety and health, please wear a lab coat, disposable gloves and a mask while handling the reagents.

3. Experimental results can be affected by many factors. Handling related to this product is limited to the product itself and does not cover any other compensation.

4. Mix the 5× G250 dye solution by inverting the bottle 3-5 times before use. Dilute 1 volume of the 5× dye solution with 4 volumes of double-distilled water to obtain the 1× working dye.

5. Dilute the sample with the same solvent that was used for the protein sample; PBS or 0.9 % NaCl can also be used for convenience. Several dilution steps (for example 2-fold, 4-fold and 8-fold) are recommended so that the reading falls in the second half of the standard curve.

6. Allow 3-5 minutes at room temperature for colour development before reading the absorbance; the reading should be completed within a short time because the dye-protein complex keeps developing.

Ordering & shipping

  • Minimum order: 1 unit
  • Lead time: varies with order quantity and specifications. Please consult your local distributor or our sales team for confirmation
  • Payment: T/T 100% in advance; PayPal; Alibaba Trade Assurance
  • Shipping: FedEx / DHL / UPS express; cold-chain packing available on request
  • Price: USD, per unit (100T)

Partial purchase records (19)

UsernameQuantitybought time
Ca***12026-06-05
Se***22024-08-10
Ka***12024-07-06
Ca***22024-06-24
Br***22024-05-20
Total 19 records, divided into4 pages. First Prev Next Last

Leave a message

* To protect against spam, please pass the CAPTCHA test below.

Newsletter

Sign up
0 0