Details
Product Description:
The kit determines the protein concentration of a sample with the Bradford method. Coomassie Brilliant Blue G-250 dye binds to protein in acidic solution and the position of the dye's maximum absorption peak shifts from 465 nm to 595 nm. Within a certain concentration range the absorbance measured at 595 nm (A595) is proportional to the protein concentration of the sample, so the protein content is obtained from a standard curve prepared with the protein standard supplied with the kit.
The Bradford assay is not affected by most of the chemicals present in a sample. The concentration of 2-mercaptoethanol in the sample may be as high as 1 M and the concentration of dithiothreitol (DTT) as high as 5 mM without influencing the result. Higher concentrations of detergents do interfere: the concentration of SDS has to stay below 0.1 %, that of Triton X-100 below 0.1 % and that of Tween 20, Tween 60 and Tween 80 below 0.06 %. For samples containing detergents, a BCA protein assay kit is recommended.
Two formats are described for the kit. In the microplate format the samples and the standards are placed in the wells of a 96-well plate, the diluted dye reagent is added and the absorbance is read with a microplate reader. When no microplate reader is available the colour reaction can be carried out in centrifuge tubes and the absorbance read in a cuvette with a spectrophotometer. The kit is intended for the quantitative determination of protein concentration in biological samples.
Specifications:
| Parameter | Value |
| Detection method | Colorimetric (Coomassie Brilliant Blue G-250) |
| Wavelength | 595 nm; the absorbance can also be read at any wavelength between 560 nm and 610 nm |
| Detection instrument | Microplate reader with a 96-well plate, or a visible spectrophotometer with a cuvette |
| Principle | Bradford method |
| Research area | Protein extraction and quantification |
| Response type | Increasing (absorbance rises with protein concentration) |
| Standard concentrations | 0, 0.02, 0.04, 0.06, 0.08, 0.12, 0.16 and 0.2 mg/mL BSA |
| Protein standard | 5 mg/mL BSA, 1 mL |
| Kit size | 100 T (2,500 microplate wells) |
| Storage | 2-8 ℃ for the dye solution and the PBS diluent; -20 ℃ for the protein standard |
| Shipping | Refrigerated |
| Shelf life | 12 months |
Kit Components:
| Component | Size | Storage |
| 5× G250 dye solution | 100 mL | 2-8 ℃ |
| PBS diluent | 30 mL | 2-8 ℃ |
| Protein standard (5 mg/mL BSA) | 1 mL | -20 ℃ |
The protein standard is supplied as a separate accessory; store it at -20 ℃ immediately after receipt.
Equipment and consumables required but not supplied: microplate reader (or visible spectrophotometer with cuvette), 96-well plate, adjustable pipettes, distilled water and clean tubes.
Storage & Shelf Life:
The kit is shipped refrigerated. On arrival store the 5× G250 dye solution and the PBS diluent at 2-8 ℃ and the protein standard at -20 ℃. Under the recommended storage conditions the kit is stable for 12 months. The 1× G250 working dye prepared by diluting the 5× dye solution with double-distilled water can be kept at 4 ℃ for one week.
Notes:
1. This product is for research use only. It is not intended for pharmaceutical, clinical diagnostic or therapeutic use, nor for food or cosmetic applications. Do not store it in ordinary residential areas.
2. For your safety and health, please wear a lab coat, disposable gloves and a mask while handling the reagents.
3. Experimental results can be affected by many factors. Handling related to this product is limited to the product itself and does not cover any other compensation.
4. Mix the 5× G250 dye solution by inverting the bottle 3-5 times before use. Dilute 1 volume of the 5× dye solution with 4 volumes of double-distilled water to obtain the 1× working dye.
5. Dilute the sample with the same solvent that was used for the protein sample; PBS or 0.9 % NaCl can also be used for convenience. Several dilution steps (for example 2-fold, 4-fold and 8-fold) are recommended so that the reading falls in the second half of the standard curve.
6. Allow 3-5 minutes at room temperature for colour development before reading the absorbance; the reading should be completed within a short time because the dye-protein complex keeps developing.
Ordering & shipping
Partial purchase records (19)
| Username | Quantity | bought time |
| Ca*** | 1 | 2026-06-05 |
| Se*** | 2 | 2024-08-10 |
| Ka*** | 1 | 2024-07-06 |
| Ca*** | 2 | 2024-06-24 |
| Br*** | 2 | 2024-05-20 |
Leave a message