Details
| Storage Conditions | 2-8℃ |
| Operation Steps | Before use, please add absolute ethanol to Buffer GD and Wash Buffer PW, refer to the label on the bottle for the volume to add; 1. Take 1-5 ml of bacterial culture, centrifuge at 10,000 rpm (11,500×g) for 1 minute, and remove the supernatant as much as possible; 2. Add 200 μL Buffer GA to the bacterial pellet, vortex until the bacteria are completely resuspended. Note: For Gram-positive bacteria with hard-to-break cell walls, skip step 2 and add lysozyme solution for cell wall disruption. The specific method is: add 110 μL buffer (20mM Tris, pH 8.0; 2mM Na2-EDTA; 1.2% Triton), and 70 μL lysozyme solution (50 mg/mL, customer-provided, catalog number: RT401), treat at 37℃ for over 30 minutes. If RNA removal is needed, add 4 μL RNase A (100 mg/mL) solution (customer-provided, catalog number: RT405-12), vortex for 15 seconds, and let stand at room temperature for 5 minutes; 3. Add 20 μL Proteinase K solution to the tube, mix well; 4. Add 220 μL Buffer GB, vortex for 15 seconds, place at 70℃ for 10 minutes; the solution should become clear. Briefly centrifuge to remove droplets from the inner wall of the tube cap. Note: When adding Buffer GB, a white precipitate may form, which usually disappears at 70℃ and does not affect subsequent experiments. If the solution does not become clear, it indicates incomplete cell lysis, which may result in low DNA yield and impure DNA; 5. Add 220 μL absolute ethanol, vortex thoroughly for 15 seconds; flocculent precipitate may appear at this point. Briefly centrifuge to remove droplets from the inner wall of the tube cap; 6. Transfer the solution and flocculent precipitate from the previous step into an adsorption column CB3 (place the column in a collection tube), centrifuge at 12,000 rpm (13,400×g) for 30 seconds, discard the waste liquid, and place the adsorption column CB3 back into the collection tube; 7. Add 500 μL Buffer GD to the adsorption column CB3 (please check if absolute ethanol has been added before use), centrifuge at 12,000 rpm (13,400×g) for 30 seconds, discard the waste liquid, and place the adsorption column CB3 back into the collection tube; 8. Add 600 μL Wash Buffer PW to the adsorption column CB3 (please check if absolute ethanol has been added before use), centrifuge at 12,000 rpm (13,400×g) for 30 seconds, discard the waste liquid, and place the adsorption column CB3 back into the collection tube; 9. Repeat operation step 8; 10. Place the adsorption column CB3 back into the collection tube, centrifuge at 12,000 rpm (13,400×g) for 2 minutes, discard the waste liquid. Let the adsorption column CB3 stand at room temperature for several minutes to completely dry any residual wash buffer in the adsorption material. Note: This step aims to remove residual wash buffer from the adsorption column, as residual ethanol in the wash buffer can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.); 11. Transfer the adsorption column CB3 into a clean centrifuge tube, add 50-200 μL Elution Buffer TE dropwise to the center of the adsorption membrane, let stand at room temperature for 2-5 minutes, centrifuge at 12,000 rpm (13,400×g) for 2 minutes, and collect the solution into the centrifuge tube. Note: The volume of elution buffer should not be less than 50 μL, as too small a volume affects recovery efficiency. The pH value of the elution buffer significantly impacts elution efficiency. If using ddH2O as the eluent, ensure its pH is between 7.0-8.5; a pH below 7.0 will reduce elution efficiency; and DNA products should be stored at -20℃ to prevent DNA degradation. To increase the yield of genomic DNA, the centrifuged solution can be added back to the adsorption column CB3, let stand at room temperature for 2 minutes, and centrifuge at 12,000 rpm (13,400×g) for 2 minutes; |
| Sharing Method | Non-profit Sharing |
? Notes:
Ordering & shipping
Partial purchase records (0)
Leave a message
+86 0571 56623320
[email protected]
+86 18668110335

Scan Wechat Qrcode
