Details
| Storage Conditions | 2-8°C |
| Procedure | Before use, add anhydrous ethanol to Buffer GD and Wash Solution PW; refer to the bottle labels for the volume to add; 1. Take 1-5 ml of bacterial culture, centrifuge at 10,000 rpm (11,500×g) for 1 min, and remove the supernatant as thoroughly as possible; 2. Add 200 μL Buffer GA to the pellet, and vortex until the pellet is completely resuspended. Note: For Gram-positive bacteria with tough cell walls, skip step 2 and perform cell wall digestion using lysozyme solution. Specific method: Add 110 μL buffer (20 mM Tris, pH 8.0; 2 mM Na2-EDTA; 1.2% Triton) and 70 μL lysozyme solution (50 mg/mL, prepared by the user, Cat. No.: RT401), and incubate at 37°C for over 30 min. If RNA removal is required, add 4 μL RNase A (100 mg/mL) solution (prepared by the user, Cat. No.: RT405-12), vortex for 15 sec, and let stand at room temperature for 5 min; 3. Add 20 μL Proteinase K solution to the tube and mix well; 4. Add 220 μL Buffer GB, vortex for 15 sec, and incubate at 70°C for 10 min. The solution should become clear. Briefly centrifuge to remove droplets from the lid. Note: A white precipitate may form when Buffer GB is added, which usually disappears during incubation at 70°C and does not affect subsequent steps. If the solution does not become clear, it indicates incomplete cell lysis, which may result in low DNA yield and impure extracted DNA; 5. Add 220 μL anhydrous ethanol, vortex thoroughly for 15 sec. A flocculent precipitate may appear at this stage. Briefly centrifuge to remove droplets from the lid; 6. Transfer the solution and any precipitate from the previous step into a CB3 adsorption column (placed in a collection tube), centrifuge at 12,000 rpm (13,400×g) for 30 sec, discard the waste liquid, and place the CB3 column back into the collection tube; 7. Add 500 μL Buffer GD to the CB3 adsorption column (ensure anhydrous ethanol has been added before use), centrifuge at 12,000 rpm (13,400×g) for 30 sec, discard the waste liquid, and place the CB3 column back into the collection tube; 8. Add 600 μL Wash Solution PW to the CB3 adsorption column (ensure anhydrous ethanol has been added before use), centrifuge at 12,000 rpm (13,400×g) for 30 sec, discard the waste liquid, and place the CB3 column back into the collection tube; 9. Repeat step 8; 10. Place the CB3 column back into the collection tube, centrifuge at 12,000 rpm (13,400×g) for 2 min, and discard the waste liquid. Leave the CB3 column at room temperature for several minutes to completely dry any residual wash solution from the adsorption material. Note: This step removes residual wash solution from the column. Residual ethanol in the wash solution can interfere with subsequent enzymatic reactions (e.g., restriction digestion, PCR); 11. Transfer the CB3 column into a clean centrifuge tube, and add 50-200 μL Elution Buffer TE dropwise to the center of the adsorption membrane. Let stand at room temperature for 2-5 min, then centrifuge at 12,000 rpm (13,400×g) for 2 min to collect the solution in the centrifuge tube. Note: The volume of Elution Buffer should not be less than 50 μL, as smaller volumes reduce recovery efficiency. The pH of the elution buffer significantly affects elution efficiency. If using ddH2O as the eluent, ensure its pH is within 7.0-8.5; a pH below 7.0 reduces elution efficiency; DNA products should be stored at -20°C to prevent degradation. To increase genomic DNA yield, the collected solution can be reapplied to the CB3 column, allowed to stand at room temperature for 2 min, and then centrifuged at 12,000 rpm (13,400×g) for 2 min; |
| Sharing Method | Public Welfare Sharing |
? Notes:
Ordering & shipping
Partial purchase records (0)
Leave a message
+86 0571 56623320
[email protected]
+86 18668110335

Scan Wechat Qrcode
