Details
| Storage Conditions | 2-8℃ |
| Operational Steps | Before use, please add anhydrous ethanol to buffer GD and rinse solution PW. Refer to the label on the bottle for the required volume; 1. Take 1-5ml of bacterial culture, centrifuge at 10,000rpm (11,500×g) for 1 minute, and remove the supernatant as much as possible; 2. Add 200μL of buffer GA to the bacterial pellet, and vortex until the pellet is completely suspended. Note: For Gram-positive bacteria with difficult-to-break cell walls, skip step 2 and use lysozyme solution for cell wall disruption. Specific method: Add 110μL of buffer (20mM Tris, pH8.0; 2mM Na2-EDTA; 1.2% Triton) and 70μL of lysozyme solution (50mg/mL, provided by the customer, catalog number: RT401), and incubate at 37℃ for more than 30 minutes. If RNA removal is needed, add 4μL of RNase A (100mg/mL) solution (provided by the customer, catalog number: RT405-12), vortex for 15 seconds, and let it stand at room temperature for 5 minutes; 3. Add 20μL of Proteinase K solution to the tube and mix well; 4. Add 220μL of buffer GB, vortex for 15 seconds, and incubate at 70℃ for 10 minutes. The solution should become clear. Briefly centrifuge to remove water droplets from the inner wall of the tube cap. Note: A white precipitate may form when adding buffer GB, which generally disappears upon incubation at 70℃ and will not affect subsequent experiments. If the solution does not become clear, it indicates incomplete cell lysis, which may result in low DNA yield and impure DNA extraction; 5. Add 220μL of anhydrous ethanol, vortex thoroughly for 15 seconds. Flocculent precipitate may appear at this point. Briefly centrifuge to remove water droplets from the inner wall of the tube cap; 6. Transfer the solution and flocculent precipitate from the previous step into a CB3 adsorption column (place the adsorption column in a collection tube), centrifuge at 12,000rpm (13,400×g) for 30 seconds, discard the waste liquid, and place the CB3 adsorption column back into the collection tube; 7. Add 500μL of buffer GD to the CB3 adsorption column (check if anhydrous ethanol has been added before use), centrifuge at 12,000rpm (13,400×g) for 30 seconds, discard the waste liquid, and place the CB3 adsorption column back into the collection tube; 8. Add 600μL of rinse solution PW to the CB3 adsorption column (check if anhydrous ethanol has been added before use), centrifuge at 12,000rpm (13,400×g) for 30 seconds, discard the waste liquid, and place the CB3 adsorption column back into the collection tube; 9. Repeat step 8; 10. Place the CB3 adsorption column back into the collection tube, centrifuge at 12,000rpm (13,400×g) for 2 minutes, discard the waste liquid. Let the CB3 adsorption column stand at room temperature for a few minutes to thoroughly air-dry any residual rinse solution from the adsorption material. Note: The purpose of this step is to remove residual rinse solution from the adsorption column. Residual ethanol in the rinse solution may affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.); 11. Transfer the CB3 adsorption column into a clean centrifuge tube, add 50-200μL of elution buffer TE dropwise to the center of the adsorption membrane, let it stand at room temperature for 2-5 minutes, centrifuge at 12,000rpm (13,400×g) for 2 minutes, and collect the solution into the centrifuge tube. Note: The volume of elution buffer should not be less than 50μL, as a smaller volume may affect recovery efficiency. The pH of the elution buffer significantly affects elution efficiency. If using ddH2O as the eluent, ensure its pH is within the range of 7.0-8.5, as a pH below 7.0 will reduce elution efficiency; DNA products should be stored at -20℃ to prevent degradation. To increase the yield of genomic DNA, the centrifuged solution can be reapplied to the CB3 adsorption column, left at room temperature for 2 minutes, and centrifuged at 12,000rpm (13,400×g) for 2 minutes; |
| Sharing Method | Public Welfare Sharing |
? Notes:
Ordering & shipping
Partial purchase records (0)
Leave a message
+86 0571 56623320
[email protected]
+86 18668110335

Scan Wechat Qrcode
