Details
| Storage Conditions | 2-8°C |
| Procedure | Before use, please add anhydrous ethanol to Buffer GD and Wash Buffer PW; refer to the label on the bottle for the volume; 1. Take 1-5ml of bacterial culture, centrifuge at 10,000rpm (11,500×g) for 1min, and remove the supernatant as completely as possible; 2. Add 200μL Buffer GA to the bacterial pellet, vortex until the pellet is completely resuspended. Note: For Gram-positive bacteria with tough cell walls, skip step 2 and use lysozyme for cell wall digestion. Specific method: Add 110μL buffer (20mM Tris, pH8.0; 2mM Na2-EDTA; 1.2% Triton) and 70μL lysozyme solution (50mg/mL, prepared by user, catalog number: RT401), incubate at 37°C for over 30min. If RNA removal is needed, add 4μL RNase A (100mg/mL) solution (prepared by user, catalog number: RT405-12), vortex for 15sec, and let stand at room temperature for 5min; 3. Add 20μL Proteinase K solution to the tube and mix well; 4. Add 220μL Buffer GB, vortex for 15sec, incubate at 70°C for 10min until the solution becomes clear, then briefly centrifuge to remove droplets from the tube cap. Note: A white precipitate may form when adding Buffer GB, which usually dissolves at 70°C and will not affect subsequent experiments. If the solution does not become clear, cell lysis is incomplete, which may result in low DNA yield and impure extracted DNA; 5. Add 220μL anhydrous ethanol, vortex thoroughly for 15sec; flocculent precipitate may appear at this stage, briefly centrifuge to remove droplets from the tube cap; 6. Transfer the solution and any precipitate from the previous step to an adsorption column CB3 (placed in a collection tube), centrifuge at 12,000rpm (13,400×g) for 30sec, discard the waste liquid, and place the adsorption column CB3 back into the collection tube; 7. Add 500μL Buffer GD to the adsorption column CB3 (ensure anhydrous ethanol has been added before use), centrifuge at 12,000rpm (13,400×g) for 30sec, discard the waste liquid, and place the adsorption column CB3 back into the collection tube; 8. Add 600μL Wash Buffer PW to the adsorption column CB3 (ensure anhydrous ethanol has been added before use), centrifuge at 12,000rpm (13,400×g) for 30sec, discard the waste liquid, and place the adsorption column CB3 back into the collection tube; 9. Repeat step 8; 10. Place the adsorption column CB3 back into the collection tube, centrifuge at 12,000rpm (13,400×g) for 2min, discard the waste liquid. Let the adsorption column CB3 stand at room temperature for a few minutes to thoroughly dry any residual wash buffer from the adsorbent material. Note: This step removes residual wash buffer from the column; ethanol residue in the wash buffer can affect subsequent enzymatic reactions (e.g., digestion, PCR); 11. Transfer the adsorption column CB3 to a clean centrifuge tube, add 50-200μL Elution Buffer TE dropwise to the center of the adsorption membrane, let stand at room temperature for 2-5min, centrifuge at 12,000rpm (13,400×g) for 2min, and collect the solution in the centrifuge tube. Note: The elution buffer volume should not be less than 50μL; too small a volume reduces recovery efficiency. The pH of the elution buffer significantly affects elution efficiency. If using ddH2O as the eluent, ensure its pH is within the range of 7.0-8.5; a pH below 7.0 will reduce elution efficiency; DNA products should be stored at -20°C to prevent degradation. To increase genomic DNA yield, the collected solution can be reapplied to the adsorption column CB3, let stand at room temperature for 2min, and centrifuge again at 12,000rpm (13,400×g) for 2min; |
| Sharing Method | Public Welfare Sharing |
? Notes:
Ordering & shipping
Partial purchase records (0)
Leave a message
+86 0571 56623320
[email protected]
+86 18668110335

Scan Wechat Qrcode
