Home > Sunlong Medical™ > ELISA KIT > Sunlong Medical™ Rat SCF ELISA Kit

Sunlong Medical™ Rat SCF ELISA Kit

Sunlong Medical™ Rat SCF ELISA Kit
Total

Product Summary

Alias:KITLG elisa kit | KIT ligand elisa kit | C-kit ligand | hematopoietic growth factor KL | Kitl | Kl1 | Kl2 | LOC60427 | LOC60428 | mast cell growth factor | Mgf | SCF | steel factor/kit ligand | stem cell factor | stem cell factor KL-1 | stem cell factor K

NO.:EL0024Ra

Species:Rat

Assay range:0.23ng/mL-15ng/mL

Sensitivity:38.4 pg/mL

Sample Volume:50 μL

Assay type:Sandwich Method

Validity:Two Years

    Number:

Details

Cat NO.:
EL0024Ra
Product:
Sunlong Medical™ Rat SCF ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
81% - 112%
Mean Spike Recovery:
0.96
CV of Intra plate:
8.3 % - 9.2 %
CV of Inter plate:
4.8 % - 7.2%
NCBI_Gene:
60427
UniProtKB:
A0A0G2JTU2

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-SCF monoclonal antibody
Rat SCF freeze-dried standard
Rat SCF detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) technique. Specific monoclonal antibodies against rat SCF are precoated on a high-affinity ELISA plate. Standard samples and test samples are added to the wells of the ELISA plate, and after incubation, the SCF present in the samples binds to the solid-phase antibodies. After washing to remove unbound substances, biotinylated detection antibodies are added and incubated, followed by washing to remove unbound biotinylated antibodies. Then, HRP-labeled streptavidin is added. After washing, TMB chromogenic substrate is added for color development while avoiding light. The intensity of the color reaction is directly proportional to the concentration of SCF in the sample. The reaction is terminated by adding a stop solution, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

Partial purchase records (18)

UsernameQuantitybought time
Qu***32024-09-12
Ke***32024-09-11
Um***22024-08-31
Sa***22024-08-31
Vi***32024-08-19
Total 18 records, divided into4 pages. First Prev Next Last

Leave a message

* To protect against spam, please pass the CAPTCHA test below.

Newsletter

Sign up
0 0