Home > Sunlong Medical™ > ELISA KIT > Sunlong Medical™ Human CCL4 (MIP-1 beta)elisa Kit

Sunlong Medical™ Human CCL4 (MIP-1 beta)elisa Kit

Sunlong Medical™ Human CCL4 (MIP-1 beta)elisa Kit
Total

Product Summary

Alias:CCL4 elisa kit | C-C motif chemokine ligand 4 elisa kit | ACT2 | AT744.1 | C-C motif chemokine 4 | CC chemokine ligand 4 | chemokine C-C motif ligand 4 | G-26 | G-26 T-lymphocyte-secreted protein | HC21 | LAG-1 | LAG1 | lymphocyte activation gene 1 prot

NO.:EL0062Hu

Species:Human

Assay range:15.63pg/mL-1000pg/mL

Sensitivity:3.58 pg/mL

Sample Volume:20 μL

Assay type:Sandwich Method

Validity:Two Years

    Number:

Details

Cat NO.:
EL0062Hu
Product:
Sunlong Medical™ Human CCL4 (MIP-1 beta) ELISA Kit
Storage
4℃ (unopened) for two years
Shipping Condition
4℃
Sample Type:
Serum | plasma | cell culture supernatant and other biological samples
Spike Recovery Range:
85% - 122%
Mean Spike Recovery:
0.99
CV of Intra plate:
1.8 % - 3.3 %
CV of Inter plate:
2.9 % - 3.1 %
NCBI_Gene:
6351
UniProtKB:
P13236

 

PLATFORM ELISA
PLATE Detachable 96-well plate
SIZE 96T/48T
STORAGE If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃.
DELIVERY 4℃ blue ice transportation
COMPONENTS 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-CCL4/MIP-1β monoclonal antibody
Human CCL4/MIP-1β freeze-dried standard
CCL4/MIP-1β detect Antibody
Standard Diluent
Assay Buffer(10×)
Substrate TMB
Stop Solution
Washing Buffer(20×)
Sealing Film
ASSAY PRINCIPLE This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-human CCL4 antibodies are precoated on a high-affinity ELISA plate. Standard samples, test samples, and biotinylated detection antibodies are added to the wells of the ELISA plate. After incubation, CCL4 present in the samples binds to the solid-phase antibodies and the detection antibodies. After washing to remove unbound substances, streptavidin-HRP labeled with horseradish peroxidase is added. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of CCL4 in the samples. A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm).

 

Partial purchase records (25)

UsernameQuantitybought time
Vi***32024-09-10
Za***22024-08-31
Ra***32024-08-18
Xa***12024-08-01
Xa***12024-08-01
Total 25 records, divided into5 pages. First Prev Next Last

Leave a message

* To protect against spam, please pass the CAPTCHA test below.

Newsletter

Sign up
0 0