Details
Cat NO.:
|
HS-EL0019Mo |
---|---|
Product:
|
Sunlong Medical™ Mouse CCL2/MCP-1 High Sensitivity ELISA Kit |
Storage
|
4℃ (unopened) for two years |
Shipping Condition
|
4℃ |
Sample Type:
|
Serum | plasma | cell culture supernatant and other biological samples |
Spike Recovery Range:
|
90% - 118% |
Mean Spike Recovery:
|
1.07 |
CV of Intra plate:
|
3.1% - 4.9% |
CV of Inter plate:
|
3.0% - 4.5% |
NCBI_Gene:
|
20296 |
UniProtKB:
|
P10148 |
PLATFORM | ELISA |
---|---|
PLATE | Detachable 96-well plate |
SIZE | 96T/48T |
STORAGE | If the reagent kit is unopened, it should be stored at 4℃. However, if it has been opened, the standard solution should be stored at -20℃, while the other components should be stored at 4℃. |
DELIVERY | 4℃ blue ice transportation |
COMPONENTS | 96-well polystyrene enzyme-linked immunosorbent assay (ELISA) plate coated with anti-CCL2/MCP-1 monoclonal antibody Mouse CCL2/MCP-1 freeze-dried standard CCL2/MCP-1 detect Antibody Standard Diluent HRP-labeled streptavidin Signal enhancer concentrate Signal enhancer diluent Assay Buffer(10×) Substrate TMB Stop Solution Washing Buffer(20×) Sealing Film |
ASSAY PRINCIPLE | This kit utilizes the double antibody sandwich enzyme-linked immunosorbent assay (ELISA) detection technique.Specific anti-mouse CCL2 antibodies are precoated on a high-affinity ELISA plate.Standards and test samples are added to the wells of the ELISA plate. After incubation, the CCL2 present in the samples binds to the solid-phase antibodies. After washing to remove unbound substances, biotinylated detection antibodies are added and incubated. After washing to remove unbound biotinylated antibodies, streptavidin-HRP labeled with horseradish peroxidase is added. After washing again, a signal enhancer is added and incubated. After washing to remove unbound substances, Streptavidin-HRP is added once more. After washing, a colorimetric substrate, TMB, is added and the plate is incubated in the dark for color development. The intensity of the color reaction is directly proportional to the concentration of CCL2 in the samples.A stop solution is added to terminate the reaction, and the absorbance value is measured at a wavelength of 450 nm (with a reference wavelength range of 570-630 nm). |